archive-lv.com


Web directory, archive
Search archive-lv.com:


Find domain in archive system:
archive-lv.com » LV » B » BSI.LV

Total: 134

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".

  • for Radionuclide Analysis of Liquids and Gaseous Flows HPGe Hand Held Spectrometer NitroSPEC HPGe Hand Held Detector for Field Application Gamma and X ray HP Ge Spectrometer Electrically cooled Deep water Gamma ray HP Ge Spectrometer Automated System for Water Activity Measurement in Outlet Channels of NPPs and Nuclear Enterprises Flowing HP Ge Spectrometer HP Ge Mobile Spectrometer for Field Application Waste Assay Monitor Borehole Gamma Spectrometer CdZnTe CdTe Detectors associated electronics Large Volume Spectroscopy Detectors Spectrometric Detection Probes Detector Linear Arrays Pixel Detectors Strip Detectors Electronics Multi Channel Analyzer Multispectrum Multi Channel Analyzer MS Hybrid Digital Multi Channel Analyzer DigiSpectrum Digital Miniature Multi Channel Analyzer MCA 527 Neutron Search Detector KSAR1U 06 Radiation Portal Monitors Cryostats vacuum chambers Dewar vessels PDF Catalogue Main Products HPGe Detectors Spectrometers Laboratory HPGe Spectrometer with Shield Laboratory HPGe Spectrometer with Shield APPLICATION A Coaxial HPGe Detector with Lead Shield is used to measure the specific gamma radiation of radionuclides from various types of environmental objects such as rocks minerals sludge slag soil plant sediment and particulate matter in air FEATURES Adopting precision gamma spectrometry methods Radionuclide identification and determination of their specific activity Low level of instrumental background Low threshold for radionuclide detection Separate and simultaneous measurement of activity of 100 radionuclides COMPLETE SET Detection Unit based on 10 160 efficient HPGe p type coaxial detector Lead Shield for lower back signal with a support Liquid nitrogen level monitor LN2 Monitor Multi Channel Analyzer MS Hybrid or DigiSpectrum Emulation and analysis Software By special request detector chamber holder and internal details can be made from low background materials TECHNICAL CHARACTERISTICS Parameter Value Detection limit for Cs 137 radionuclide specific activity measurement time 1 hour Bq kg 0 5 Absolute sensitivity to gamma flux for 30 efficient detector pulse quantum 4 5 x 10

    Original URL path: http://www.bsi.lv/laboratory_hpge_spectrometer_with_shield_eng.html (2012-12-23)
    Open archived version from archive


  • Gaseous Flows HPGe Hand Held Spectrometer NitroSPEC HPGe Hand Held Detector for Field Application Gamma and X ray HP Ge Spectrometer Electrically cooled Deep water Gamma ray HP Ge Spectrometer Automated System for Water Activity Measurement in Outlet Channels of NPPs and Nuclear Enterprises Flowing HP Ge Spectrometer HP Ge Mobile Spectrometer for Field Application Waste Assay Monitor Borehole Gamma Spectrometer CdZnTe CdTe Detectors associated electronics Large Volume Spectroscopy Detectors Spectrometric Detection Probes Detector Linear Arrays Pixel Detectors Strip Detectors Electronics Multi Channel Analyzer Multispectrum Multi Channel Analyzer MS Hybrid Digital Multi Channel Analyzer DigiSpectrum Digital Miniature Multi Channel Analyzer MCA 527 Neutron Search Detector KSAR1U 06 Radiation Portal Monitors Cryostats vacuum chambers Dewar vessels PDF Catalogue Main Products HPGe Detectors Spectrometers HPGe Spectrometer with Shield for Radionuclide Analysis of Liquids and Gaseous Flows HPGe Spectrometer with Shield for Radionuclide Analysis of Liquids and Gaseous Flows APPLICATION The spectrometer with shield is designed for defining the composition and activity of radionuclides in the flow of liquids and gases in automated technological processes such as those in nuclear energetics environmental monitoring and industrial applications FEATURES Definition of composition and activity of radionuclides in real time mode Display of current values for specific activity of controlled radionuclides High registration efficiency Wide range of measured activities Operation rates in fully automatic mode measurement washing purging pre starting COMPLETE SET Detection Unit based on HPGe p type coaxial detector Spectrometric device Multispectrum or DigiSpectrum Shield container with measuring unit Control unit with valves Sensors for liquid and gas flow Emulation and analysis Software TECHNICAL CHARACTERISTICS Parameter Value Energy resolution MeV 0 05 2 8 HP Ge detector efficiency 10 Detection limit for I 131 radionuclide specific activity measurement time 600 sec Bq l 1 5 x 10 3 Absolute sensitivity to gamma flux for

    Original URL path: http://www.bsi.lv/hpge_spectrometer_with_shield_or_radionuclide_analysis_of_liquids_and_gaseous_flows_eng.html (2012-12-23)
    Open archived version from archive


  • Water Activity Measurement in Outlet Channels of NPPs and Nuclear Enterprises Flowing HP Ge Spectrometer HP Ge Mobile Spectrometer for Field Application Waste Assay Monitor Borehole Gamma Spectrometer CdZnTe CdTe Detectors associated electronics Large Volume Spectroscopy Detectors Spectrometric Detection Probes Detector Linear Arrays Pixel Detectors Strip Detectors Electronics Multi Channel Analyzer Multispectrum Multi Channel Analyzer MS Hybrid Digital Multi Channel Analyzer DigiSpectrum Digital Miniature Multi Channel Analyzer MCA 527 Neutron Search Detector KSAR1U 06 Radiation Portal Monitors Cryostats vacuum chambers Dewar vessels PDF Catalogue Main Products HPGe Detectors Spectrometers HPGe Hand Held Spectrometer NitroSPEC HPGe Hand Held Spectrometer NitroSPEC APPLICATION Customs and Homeland security Environmental monitoring Waste Management Nuclear Industry Nuclear Medicine First Response FEATURES Minimal weight and size Ready for operation in 1 hour Autonomous operating time up to 20 hours Simple and cheap in maintenance and service Really competitive price COMPLETE SET standard HPGe detector Coaxial or Planar Digital Multi Channel Analyzer A nalytical software packag Touch screen display Dewar vessel Communication interface USB wireless Adaptor ACCESSORIES optional Lead Shielding with collimators Hand cart Hard sided transport case Funnel for LN2 filling Car charger Spare Battery TECHNICAL CHARACTERISTICS Parameter Value Relative efficiencies available 10 15 20 Energy range

    Original URL path: http://www.bsi.lv/hand_held_nitrospec_eng.html (2012-12-23)
    Open archived version from archive


  • Gamma and X ray HP Ge Spectrometer Electrically cooled Deep water Gamma ray HP Ge Spectrometer Automated System for Water Activity Measurement in Outlet Channels of NPPs and Nuclear Enterprises Flowing HP Ge Spectrometer HP Ge Mobile Spectrometer for Field Application Waste Assay Monitor Borehole Gamma Spectrometer CdZnTe CdTe Detectors associated electronics Large Volume Spectroscopy Detectors Spectrometric Detection Probes Detector Linear Arrays Pixel Detectors Strip Detectors Electronics Multi Channel Analyzer Multispectrum Multi Channel Analyzer MS Hybrid Digital Multi Channel Analyzer DigiSpectrum Digital Miniature Multi Channel Analyzer MCA 527 Neutron Search Detector KSAR1U 06 Radiation Portal Monitors Cryostats vacuum chambers Dewar vessels PDF Catalogue Main Products HPGe Detectors Spectrometers HPGe Hand Held Detector for Field Application HP Ge Hand Held Detector for Field Application APPLICATION Registration of Gamma and X Ray spectra for the radiological control of environmental objects industrial and agricultural products objects and plants of nuclear energetics and enterprises dealing with the storage and processing of radioactive wastes FEATURES Minimal sizes and weight Can be placed in an ordinary case Minimal time to reach the proper temperature mode for the detector after LN2 filling Minimal time for the Dewar vessel emptying from LN2 remains Convenience and simplicity of operating and servicing the device COMPLETE SET HPGe semiconductor detector for Gamma and X Ray spectroscopy representing a planar or coaxial detector with preamplifier in portable Dewar Miniature spectrometric device capable of operating with a LapTop PC or Palmtop PC Software Lead Shielding with collimators Hard sided transport case Accessories Funnel for LN2 filling Recharger etc Cable pack and documentation TECHNICAL CHARACTERISTICS Parameter Value Maximal dimensions of a planar detector which can be installed Sensitive area mm 2 Thickness mm 500 15 Energy resolution for 500 mm 2 sensitive area detector at energy 122 keV eV 560 Maximal efficiency of coaxial

    Original URL path: http://www.bsi.lv/hp_ge_hand_held_detector_for_field_application_eng.html (2012-12-23)
    Open archived version from archive


  • for Field Application Gamma and X ray HP Ge Spectrometer Electrically cooled Deep water Gamma ray HP Ge Spectrometer Automated System for Water Activity Measurement in Outlet Channels of NPPs and Nuclear Enterprises Flowing HP Ge Spectrometer HP Ge Mobile Spectrometer for Field Application Waste Assay Monitor Borehole Gamma Spectrometer CdZnTe CdTe Detectors associated electronics Large Volume Spectroscopy Detectors Spectrometric Detection Probes Detector Linear Arrays Pixel Detectors Strip Detectors Electronics Multi Channel Analyzer Multispectrum Multi Channel Analyzer MS Hybrid Digital Multi Channel Analyzer DigiSpectrum Digital Miniature Multi Channel Analyzer MCA 527 Neutron Search Detector KSAR1U 06 Radiation Portal Monitors Cryostats vacuum chambers Dewar vessels PDF Catalogue Main Products HPGe Detectors Spectrometers Gamma and X ray HP Ge Spectrometer Electrically cooled Gamma and X ray HP Ge Spectrometer Electrically cooled APPLICATION The gamma ray Detection Device is based on a HPGe detector with Electric Machine Cooling which is intended for the conversion of Gamma ray quantum energy using amplitude electric signals and their amplification for further registration with a nuclear physics apparatus It was specifically developed for long continuous operations FEATURES No liquid nitrogen necessary Detection of radiation possible in any spatial orientation Automatic restart after power supply switch off Long duration continuous function Coaxial or planar HP Ge detector can be used COMPLETE SET Detection device consisting of cryostat HP Ge detector crystal temperature sensor and heat exchanger Gas compressor cooling system with built in cryocontroller for the provision of automatic monitoring and control of operating modes for HP Ge detector and cryosystem High pressure gas pipes for connecting the cryosystem to the Detection Unit heat exchanger Spectrometric device Multispectrum or DigiSpectrum Emulation and analysis Software TECHNICAL CHARACTERISTICS Parameter Value Energy range keV 40 3000 HP Ge detector efficiency 30 Energy resolution for 30 efficiency detector keV at energy 122

    Original URL path: http://www.bsi.lv/gamma_and_xray_hp_ge_spectrometer_electrically_cooled_eng.html (2012-12-23)
    Open archived version from archive


  • and X ray HP Ge Spectrometer Electrically cooled Deep water Gamma ray HP Ge Spectrometer Automated System for Water Activity Measurement in Outlet Channels of NPPs and Nuclear Enterprises Flowing HP Ge Spectrometer HP Ge Mobile Spectrometer for Field Application Waste Assay Monitor Borehole Gamma Spectrometer CdZnTe CdTe Detectors associated electronics Large Volume Spectroscopy Detectors Spectrometric Detection Probes Detector Linear Arrays Pixel Detectors Strip Detectors Electronics Multi Channel Analyzer Multispectrum Multi Channel Analyzer MS Hybrid Digital Multi Channel Analyzer DigiSpectrum Digital Miniature Multi Channel Analyzer MCA 527 Neutron Search Detector KSAR1U 06 Radiation Portal Monitors Cryostats vacuum chambers Dewar vessels PDF Catalogue Main Products HPGe Detectors Spectrometers Deep water Gamma ray HP Ge Spectrometer Deep water Gamma ray HP Ge Spectrometer APPLICATION Deep Water gamma spectrometer is applicable to the registration of gamma radiation from radionuclides in monitoring of the sea bed for objects from marine accidents submarine storage of radioactive wastes search of lost nuclear charges inspection of radionuclide migration etc FEATURES Long lasting independent functioning at great depths Programmable control with built in microprocessor device Independent detection and accumulation of gamma spectra for a predetermined time Recording and storage of gamma spectra for an unlimited time period Possibility of reading and processing data using computers after retrieving the spectrometer COMPLETE SET HP Ge coaxial detector Cryostat combined with cryoaccumulator for detector cooling Spectrometric device with microprocessor and data transfer devices Durable waterproof housing with power supply for the spectrometer allowing spectrometer to dive to depths of up to 1000 meters External equipment for cryoaccumulator cooling and refilling with liquid nitrogen Work station equipped PC with software for spectra visualization and radionuclide identification TECHNICAL CHARACTERISTICS Parameter Value Energy range keV 60 3000 HP Ge detector efficiency 30 Energy resolution for 30 efficiency detector keV at energy 122 keV 1

    Original URL path: http://www.bsi.lv/deep_water_gamma_ray_hp_ge_spectrometer_eng.html (2012-12-23)
    Open archived version from archive


  • Field Application Gamma and X ray HP Ge Spectrometer Electrically cooled Deep water Gamma ray HP Ge Spectrometer Automated System for Water Activity Measurement in Outlet Channels of NPPs and Nuclear Enterprises Flowing HP Ge Spectrometer HP Ge Mobile Spectrometer for Field Application Waste Assay Monitor Borehole Gamma Spectrometer CdZnTe CdTe Detectors associated electronics Large Volume Spectroscopy Detectors Spectrometric Detection Probes Detector Linear Arrays Pixel Detectors Strip Detectors Electronics Multi Channel Analyzer Multispectrum Multi Channel Analyzer MS Hybrid Digital Multi Channel Analyzer DigiSpectrum Digital Miniature Multi Channel Analyzer MCA 527 Neutron Search Detector KSAR1U 06 Radiation Portal Monitors Cryostats vacuum chambers Dewar vessels PDF Catalogue Main Products HPGe Detectors Spectrometers Automated System for Water Activity Measurement in Outlet Channels of NPPs and Nuclear Enterprises Automated System for Water Activity Measurement in Outlet Channels of NPPs and Nuclear Enterprises APPLICATION Automatic monitoring of gamma ray radionuclide specific activity directly in water reservoirs in the regions of nuclear weapons testing near nuclear storage nuclear power plants and other objects of nuclear energetics FEATURES High sensitivity of radionuclide activity detection Full autonomy of measurement station data transfer via radio channel or cable channel into the point of information receiving processing and archiving Operation simplicity and system high reliability COMPLETE SET Floating monitoring station that is situated on the platform on pontoon and contains Gamma ray spectrometer based on submerged high purity germanium or scintillator detector Transmitter receiver Microprocessor device for interfaces necessary for automatic operation self diagnostic calibration Backup accumulators Accessories for station control calibration Station for receiving processing and archiving information including Radio station Decoding modem connection device with personal computer Software for spectra description nuclides identification calculation of their specific activity Device for information CD ROM recording Metrological assurance set of accessories and necessary instruments TECHNICAL CHARACTERISTICS Parameter Value Energy range

    Original URL path: http://www.bsi.lv/automated_system_for_water_activity_measurement_in_outlet_channels_of_npps_and_nuclear_enterprises_eng.html (2012-12-23)
    Open archived version from archive


  • on Planar Detector GPD Liquid Nitrogen cooled Portable HP Ge Gamma ray Spectrometer Laboratory HPGe Spectrometer with Shield HPGe Spectrometer with Shield for Radionuclide Analysis of Liquids and Gaseous Flows HPGe Hand Held Spectrometer NitroSPEC HPGe Hand Held Detector for Field Application Gamma and X ray HP Ge Spectrometer Electrically cooled Deep water Gamma ray HP Ge Spectrometer Automated System for Water Activity Measurement in Outlet Channels of NPPs and Nuclear Enterprises Flowing HP Ge Spectrometer HP Ge Mobile Spectrometer for Field Application Waste Assay Monitor Borehole Gamma Spectrometer CdZnTe CdTe Detectors associated electronics Large Volume Spectroscopy Detectors Spectrometric Detection Probes Detector Linear Arrays Pixel Detectors Strip Detectors Electronics Multi Channel Analyzer Multispectrum Multi Channel Analyzer MS Hybrid Digital Multi Channel Analyzer DigiSpectrum Digital Miniature Multi Channel Analyzer MCA 527 Neutron Search Detector KSAR1U 06 Radiation Portal Monitors Cryostats vacuum chambers Dewar vessels PDF Catalogue Main Products HPGe Detectors Spectrometers Flowing HP Ge Spectrometer Flowing HP Ge Spectrometer APPLICATION Highly efficient control of radionuclide materials with low activity FEATURES Detection Unit performs 4π geometry measurements as measuring product is moving inside germanium detector Radionuclide efficiency registration is dozens times higher than efficiency registration of standard coaxial detection unit of the

    Original URL path: http://www.bsi.lv/flowing_spectrometer_eng.html (2012-12-23)
    Open archived version from archive


archive-lv.com, 2017-08-23