  • Beijer Electronics - ODW-720-F1
    equipment EN 60950 1 dielectric strength Signal port to all other isolated ports 2 kVrms 50 Hz 1 min Power port to other isolated ports 3 kVrms 50 Hz 1 min 2 kVrms 50 Hz 1 min rated power Climatic Temperature operating 40 to 70 C 40 to 158 F Temperature storage 40 to 70 C 40 to 158 F Humidity operating 5 to 95 relative humidity Humidity storage 5 to 95 relative humidity Enclosure Enclosure UL 94 PC ABS flammability class V 1 Dimensions W x H x D 35 x 121 x 119 mm 1 37 x 4 76 x 4 68 in Weight 0 26 kg Degree of protection IP 21 Cooling Convection Mounting Horizontal on 35 mm DIN rail Mechanical IEC 60068 2 6 vibration Operating 7 5 mm 5 8 Hz 2 g 8 500 Hz IEC 60068 2 27 shock Operating 15 g 11 ms Interface specifications power Rated voltage 12 to 48 VDC and 24 VAC Operating voltage 10 to 60 VDC and 20 to 30 VAC Rated current 300 mA 12 V 150 mA 24 V 75 mA 48 V Rated frequency DC and 48 to 62 Hz Inrush current 0 2 A s Startup current 1 0 Apeak Polarity Reverse polarity protected Redundant power input Yes Isolation to RS 232 and Status port Connection Detachable screw terminal Connector size 0 75 2 5 mm AWG 18 13 Connect the unit using at least 18 AWG 0 75 mm2 wiring Shielded cable Not required Interface specifications status Port type Signal relay changeover contacts Rated voltage Up to 48 VDC Operating voltage Up to 60 VDC Contact rating 500 mA 48 VDC Contact resistance Isolation to RS 232 and Power port Connection Detachable screw terminal Connector size 0 2 2 5 mm AWG 24 13 Shielded cable Not required Interface specifications RS 232 Electrical specification EIA RS 232 Data rate 300 bit s 250 kbit s Protocol Asynchronous or synchronous Data format 9 12 bits in asynchronous mode Any type in synchronous mode Retiming Asynchronous mode only Transmission range 15 m 49 ft Isolation to Status and Power port Connection 9 pin D sub female DCE Shielded cable Not required except when installed in railway applications as signalling and telecommunications apparatus and located close to rails Conductive housing Isolated to all other circuits and housings Technical Data ODW 720 F1 EX ODW 720 F1 EX Product description Status Active Article number 3651 3721 Ports 1 x Detachable screw terminal Status 1 x RS 232 1 x LC Duplex or LC Simplex FX Fibre Description Point to Point Fibre Converter RS 232 Warranty period 5 Years Approvals Hazardous locations ATEX EN 60079 0 and EN 60079 15 Reliability prediction Service life operating Operating 10 year EMC Electromagnetic Compatibility EN 61000 6 1 Immunity residential environments EN 61000 6 2 Immunity industrial environments EN 61000 6 3 Emission residential environments EN 61000 6 4 Emission industrial environments EN 55022 Emission IT equipment class A EN

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/291976B6728CCC39C12578930034B860 (2012-12-23)
    Open archived version from archive


  • Beijer Electronics - ODW-720-F2
    EN 60950 1 IT equipment EN 60950 1 dielectric strength Signal port to all other isolated ports 2 kVrms 50 Hz 1 min Power port to other isolated ports 3 kVrms 50 Hz 1 min 2 kVrms 50 Hz 1 min rated power Climatic Temperature operating 40 to 60 C 40 to 140 F Temperature storage 40 to 60 C 40 to 140 F Humidity operating 5 to 95 relative humidity Humidity storage 5 to 95 relative humidity Enclosure Enclosure UL 94 PC ABS flammability class V 1 Dimensions W x H x D 35 x 121 x 119 mm 1 37 x 4 76 x 4 68 in Weight 0 26 kg Degree of protection IP 21 Cooling Convection Mounting Horizontal on 35 mm DIN rail Mechanical IEC 60068 2 6 vibration Operating 7 5 mm 5 8 Hz 2 g 8 500 Hz IEC 60068 2 27 shock Operating 15 g 11 ms Interface specifications power Rated voltage 12 to 48 VDC and 24 VAC Operating voltage 10 to 60 VDC and 20 to 30 VAC Rated current 400 mA 12 V 200 mA 24 V 100 mA 48 V Rated frequency DC and 48 to 62 Hz Inrush current 0 2 A s Startup current 1 0 Apeak Polarity Reverse polarity protected Redundant power input Yes Isolation to RS 232 and Status port Connection Detachable screw terminal Connector size 0 75 2 5 mm AWG 18 13 Connect the unit using at least 18 AWG 0 75 mm2 wiring Shielded cable Not required Interface specifications status Port type Signal relay changeover contacts Rated voltage Up to 48 VDC Operating voltage Up to 60 VDC Contact rating 500 mA 48 VDC Contact resistance Isolation to RS 232 and Power port Connection Detachable screw terminal Connector size 0 2 2 5 mm AWG 24 13 Shielded cable Not required Interface specifications RS 232 Electrical specification EIA RS 232 Data rate 300 bit s 250 kbit s Protocol Asynchronous or synchronous Data format 9 12 bits in asynchronous mode Any type in synchronous mode Retiming Asynchronous mode only Transmission range 15 m 49 ft Isolation to Status and Power port Connection 9 pin D sub female DCE Shielded cable Not required except when installed in railway applications as signalling and telecommunications apparatus and located close to rails Conductive housing Isolated to all other circuits and housings Technical Data ODW 720 F2 EX ODW 720 F2 EX Product description Status Active Article number 3651 3722 Ports 1 x Detachable screw terminal Status 1 x RS 232 1 x LC Duplex or LC Simplex FX Fibre Description Ring Multidrop Fibre Converter RS 232 Warranty period 5 Years Approvals Hazardous locations ATEX EN 60079 0 and EN 60079 15 Reliability prediction Service life operating Operating 10 year EMC Electromagnetic Compatibility EN 61000 6 1 Immunity residential environments EN 61000 6 2 Immunity industrial environments EN 61000 6 3 Emission residential environments EN 61000 6 4 Emission industrial environments EN 55022 Emission IT equipment

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/5B9B8CFD71D5194FC12578930034BCD9 (2012-12-23)
    Open archived version from archive

  • Beijer Electronics - ODW-730-F1
    EN 60950 1 dielectric strength Signal port to all other isolated ports 2 kVrms 50 Hz 1min Power port to other isolated ports 3 kVrms 50 Hz 1min 2 kVrms 50 Hz 1min rated power Climatic Temperature operating 40 to 70 C 40 to 158 F Temperature storage 40 to 70 C 40 to 158 F Humidity operating 5 to 95 relative humidity Humidity storage 5 to 95 relative humidity Enclosure Enclosure UL 94 PC ABS flammability class V 1 Dimensions W x H x D 35 x 121 x 119 mm 1 37 x 4 76 x 4 68 in Weight 0 26 kg Degree of protection IP 21 Cooling Convection Mounting Horizontal on 35 mm DIN rail Mechanical IEC 60068 2 6 vibration Operating 7 5 mm 5 8 Hz 2 g 8 500 Hz IEC 60068 2 27 shock Operating 15 g 11 ms Interface specifications power Rated voltage 12 to 48 VDC and 24 VAC Operating voltage 10 to 60 VDC and 20 to 30 VAC Rated current 300 mA 12 V 150 mA 24 V 75 mA 48 V Rated frequency DC and 48 to 62 Hz Inrush current 0 2 A s Startup current 1 0 Apeak Polarity Reverse polarity protected Redundant power input Yes Isolation to RS 485 and Status port Connection Detachable screw terminal Connector size 0 75 2 5 mm AWG 18 13 Connect the unit using at least 18 AWG 0 75 mm2 wiring Shielded cable Not required Interface specifications status Port type Signal relay changeover contacts Rated voltage Up to 48 VDC Operating voltage Up to 60 VDC Contact rating 500 mA 48 VDC Contact resistance Isolation to RS 485 and Power port Connection Detachable screw terminal Connector size 0 2 2 5 mm AWG 24 13 Shielded cable Not required Interface specifications RS 422 485 Electrical specification EIA RS 485 2 wire or 4 wire twisted pair Data rate 300 bit s 1 5 Mbit s Data format 9 12 bits Protocol Start bit followed by 8 11 bits Retiming Yes Turning time One tbit tbit 1 Baud rate Baud rate in bit s Transmission range Settings 120 Ohm termination and failsafe biasing 680 Ohm Protection Installation Fault Tolerant up to 60 V Isolation to Status and Power port Connection Detachable screw terminal Connector size 0 2 2 5 mm AWG 24 13 Shielded cable Not required Technical Data ODW 730 F1 EX ODW 730 F1 EX Product description Status Active Article number 3651 3731 Ports 1 x Detachable screw terminal Status 1 x RS 422 485 1 x LC Duplex or LC Simplex FX Fibre Description Point to Point Fibre Converter RS 422 485 Warranty period 5 Years Approvals Hazardous locations ATEX EN 60079 0 and EN 60079 15 Reliability prediction Service life operating Operating 10 year EMC Electromagnetic Compatibility EN 61000 6 1 Immunity residential environments EN 61000 6 2 Immunity industrial environments EN 61000 6 3 Emission residential environments EN 61000 6 4 Emission industrial

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/EC67374AAEDBFB4AC12578930034C107 (2012-12-23)
    Open archived version from archive


  • Beijer Electronics - ODW-730-F2
    1 IT equipment EN 60950 1 dielectric strength Signal port to all other isolated ports 2 kVrms 50 Hz 1min Power port to other isolated ports 3 kVrms 50 Hz 1min 2 kVrms 50 Hz 1min rated power Climatic Temperature operating 40 to 60 C 40 to 140 F Temperature storage 40 to 70 C 40 to 158 F Humidity operating 5 to 95 relative humidity Humidity storage 5 to 95 relative humidity Enclosure Enclosure UL 94 PC ABS flammability class V 1 Dimensions W x H x D 35 x 121 x 119 mm 1 37 x 4 76 x 4 68 in Weight 0 26 kg Degree of protection IP 21 Cooling Convection Mounting Horizontal on 35 mm DIN rail Mechanical IEC 60068 2 6 vibration Operating 7 5 mm 5 8 Hz 2 g 8 500 Hz IEC 60068 2 27 shock Operating 15 g 11 ms Interface specifications power Rated voltage 12 to 48 VDC and 24 VAC Operating voltage 10 to 60 VDC and 20 to 30 VAC Rated current 300 mA 12 V 150 mA 24 V 75 mA 48 V Rated frequency DC and 48 to 62 Hz Inrush current 0 2 A s Startup current 1 0 Apeak Polarity Reverse polarity protected Redundant power input Yes Isolation to RS 485 and Status port Connection Detachable screw terminal Connector size 0 75 2 5 mm AWG 18 13 Connect the unit using at least 18 AWG 0 75 mm wiring Shielded cable Not required Interface specifications status Port type Signal relay changeover contacts Rated voltage Up to 48 VDC Operating voltage Up to 60 VDC Contact rating 500 mA 48 VDC Contact resistance Isolation to RS 485 and Power port Connection Detachable screw terminal Connector size 0 2 2 5 mm AWG 24 13 Shielded cable Not required Interface specifications RS 422 485 Electrical specification EIA RS 485 2 wire or 4 wire twisted pair Data rate 300 bit s 1 5 Mbit s Data format 9 12 bits Protocol Start bit followed by 8 11 bits Retiming Yes Turning time One tbit tbit 1 Baud rate Baud rate in bit s Transmission range Settings 120 Ohm termination and failsafe biasing 680 Ohm Protection Installation Fault Tolerant up to 60 V Isolation to Status and Power port Connection Detachable screw terminal Connector size 0 2 2 5 mm AWG 24 13 Shielded cable Not required Technical Data ODW 730 F2 EX ODW 730 F2 EX Product description Status Active Article number 3651 3732 Ports 1 x Detachable screw terminal Status 1 x RS 422 485 1 x LC Duplex or LC Simplex FX Fibre Description Point to Point Fibre Converter RS 422 485 Warranty period 5 Years Approvals Hazardous locations ATEX EN 60079 0 and EN 60079 15 Reliability prediction Service life operating Operating 10 year EMC Electromagnetic Compatibility EN 61000 6 1 Immunity residential environments EN 61000 6 2 Immunity industrial environments EN 61000 6 3 Emission residential environments EN 61000 6

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/FA2BEE8FDD7B556BC12578930034C841 (2012-12-23)
    Open archived version from archive

  • Beijer Electronics - TDW-33
    Telephone Network PSTN 1 x RS 232 Description Industrial Telephone Modem Warranty period 5 Years Standard compliance PSTN CS 03 Part 1 issue 9 FCC part 68 TIA 968 A ETSI TS103 021 1 ETSI TS103 021 2 ETSI TS103 021 3 AS ACIF S002 AS ACIF S006 Reliability prediction Service life operating Operating 10 year EMC Electromagnetic Compatibility EN 55024 Immunity IT equipment EN 55022 Emission IT equipment EN 61000 6 1 Immunity residential environments EN 61000 6 2 Immunity industrial environments EN 61000 6 3 Emission residential environments EN 61000 6 4 Emission industrial environments FCC part 15 Class B EN 50121 4 Railway signalling and telecommunications apparatus IEC 62236 4 Railway signalling and telecommunications apparatus EMC specifications EN 61000 4 2 ESD Enclosure contact 6 kV Enclosure air 8 kV IEC 61000 4 3 RF field AM modulated Enclosure 20 V m 80 2700 MHz 1 kHz sine 80 AM ENV 50204 RF field 900 MHz Enclosure 20 V m pulse modulated 200 Hz 900 5 MHz EN 61000 4 4 fast transients Signal ports 2 kV Power ports 2 kV EN 61000 4 5 surge Signal ports unbalanced 2 kV line to earth 2 kV line to line Signal ports balanced 2 kV line to earth 1 kV line to line Power ports 2 kV line to earth 2 kV line to line EN 61000 4 6 conducted RF immunity Signal ports 10 V 80 AM 1 kHz 0 15 80 MHz Power ports 10 V 80 AM 1 kHz 0 15 80 MHz EN 61000 4 8 power frequency magnetic field Enclosure 100 A m 50 Hz 16 7 Hz 0 Hz EN 61000 4 9 pulsed magnetic field Enclosure 300 A m 6 4 16 μs pulse EN 61000 4 11 Voltage dips and interruption AC power ports 10 5 000 ms interruption 10 500 ms 30 reduction 100 1 000 ms 60 reduction EN 61000 4 16 Mains freq 50 Hz Signal ports 100 V 50 Hz line to earth SS 436 15 03 Mains freq 50 Hz Signal ports 250 V 50 Hz line to line EN 61000 4 29 voltage dips and interruption DC power ports 10 100 ms interruption 10 ms 30 reduction 10 ms 60 reduction 20 above 20 below rated voltage EN 55022 radiated RF emission Class B FCC part 15 radiated RF emission Class B EN 55022 conducted emission AC power ports class B PSTN class B DC power ports class B FCC part 15 conducted emission AC power ports class B Safety EN 60950 1 dielectric strength Signal port to other isolated ports 2 kVrms 50 Hz 1 min Power port to other isolated ports 3 kVrms 50 Hz 1 min 2 kVrms 50 Hz 1 min rated power Safety UL IEC EN 60950 1 IT equipment Climatic Temperature operating 25 to 70 C 13 to 158 F Temperature storage 40 to 70 C 40 to 158 F Humidity operating 5 to 95 relative humidity non

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/BACBEB89B363DF67C125789300343F2C (2012-12-23)
    Open archived version from archive

  • Beijer Electronics - RM-80
    Local offices Support About us Operations Development Quality Environmental Policy Careers Group Information HMI operator communication Data communication Ethernet switches Ethernet extenders Routers Converters Modems Wireless Wireless Ethernet RM 80 RM 240 Communication PC RTU utility controller Accessories SCADA Drive systems Control systems Decentralized I O systems Safety systems Robots Components Products Data communication Wireless Wireless Ethernet RM 80 Wireless Ethernet Access point and Client RM 80 The RM 80

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/81B389FC833A427AC125789300349ECB (2012-12-23)
    Open archived version from archive

  • Beijer Electronics - RM-240
    Local offices Support About us Operations Development Quality Environmental Policy Careers Group Information HMI operator communication Data communication Ethernet switches Ethernet extenders Routers Converters Modems Wireless Wireless Ethernet RM 80 RM 240 Communication PC RTU utility controller Accessories SCADA Drive systems Control systems Decentralized I O systems Safety systems Robots Components Products Data communication Wireless Wireless Ethernet RM 240 WLAN Access point and Client RM 240 The RM 240 provides

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/2E42661AF9629688C12578930034A7CE (2012-12-23)
    Open archived version from archive

  • Beijer Electronics - JetBox 8150
    Communication PC Communication PCs JetBox 8150 JetBox 8180 RTU utility controller Accessories SCADA Drive systems Control systems Decentralized I O systems Safety systems Robots Components Products Data communication Communication PC Communication PCs JetBox 8150 VIA Eden V4 1GHz based industrial communication PC JetBox 8150 The JetBox 8150 is a VIA Eden V4 1GHz based industrial communication PC with system memory 1GB DDRII RAM and built in media processor for multimedia