archive-lv.com


Web directory, archive
Search archive-lv.com:


Find domain in archive system:
archive-lv.com » LV » B » BEIJER.LV

Total: 492

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Beijer Electronics - DDW-222
    resilience a ring of DDW 222s can be created using the Westermo FRNT protocol This is configured using the simple web interface For network management SNMP provides an industry standard solution allowing the DDW 222 to be used as part of a large network Downloads Technical data DDW 222 Product description Status Active Article number 3642 0220 Ports 4 x 10 100 Base TX RJ 45 1 x RS 232 9 pin D sub Description Ethernet extender with serial support Warranty period 5 Years Approvals Hazardous locations ATEX EN 60079 0 and EN 60079 15 Ex nA IIC T4 Gc FM Approvals Class 1 Div 2 Standard compliance SHDSL NEMKO ITU T G 991 2 Reliability prediction MTBF operating 700 000 hours 25 C MIL HDBK 217F EMC Electromagnetic Compatibility EN 61000 6 2 Immunity industrial environments EN 55024 Immunity IT equipment EN 61000 6 4 Emission industrial environments FCC part 15 Class A EN 50121 4 Railway signalling and telecommunications apparatus EMC specifications EN 61000 4 2 ESD Enclosure contact 6 kV Enclosure air 8 kV IEC 61000 4 3 RF field AM modulated Enclosure 20 V m 80 AM 1 kHz 80 1000 MHz 10 V m 80 AM 1 kHz 1400 2100 MHz 5 V m 80 AM 1 kHz 2100 2500 MHz 1 V m 80 AM 1 kHz 2500 2700 MHz EN 61000 4 4 fast transients Signal ports 2 kV Power ports 2 kV EN 61000 4 5 surge Signal ports balanced 2 kV line to earth 1 kV line to line Power ports 2 kV line to earth 2 kV line to line EN 61000 4 6 conducted RF immunity Signal ports 10 V 80 AM 1 kHz 0 15 80 MHz Power ports 10 V 80 AM 1 kHz 0 15 80 MHz EN 61000 4 8 power frequency magnetic field Enclosure 300 A m EN 61000 4 9 pulsed magnetic field Enclosure 300 A m EN 61000 4 16 Mains freq 50 Hz Signal ports 100 V 50 Hz line to earth SS 436 15 03 Mains freq 50 Hz Signal ports 250 V 50 Hz line to line EN 61000 4 29 voltage dips and interruption DC power ports 10 100 ms interruption 10 ms 30 reduction 10 ms 60 reduction 20 above 20 below rated voltage EN 55022 radiated RF emission Enclosure class A FCC part 15 radiated RF emission Class A EN 55022 conducted emission DC power ports class B Safety Safety EN 60950 1 IT equipment EN 60950 1 dielectric strength Signal port to other isolated ports 1500 Vrms 50 Hz 1 min Power port to other isolated ports 1500 Vrms 50 Hz 1 min Climatic Temperature operating 40 to 70 C 40 to 158 F Temperature storage 40 to 70 C 40 to 158 F Maximum surface temperature 135 C temperatur class T4 Humidity operating 5 to 95 relative humidity Humidity storage 5 to 95 relative humidity Enclosure Enclosure UL 94 aluminium zink flammability class V

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/F7096D98A8FF5570C125798A004605AD (2012-12-23)
    Open archived version from archive


  • Beijer Electronics - DDW-225
    6 kV Enclosure air 8 kV IEC 61000 4 3 RF field AM modulated Enclosure 10 V m 80 AM 1 kHz 80 1000 MHz 20 V m 80 AM 1 kHz 800 1000 MHz 10 V m 80 AM 1 kHz 1400 2100 MHz 5 V m 80 AM 1 kHz 2100 2500 MHz 1 V m 80 AM 1 kHz 2500 2700 MHz EN 61000 4 4 fast transients Signal ports 2 kV Power ports 2 kV EN 61000 4 5 surge Signal ports unbalanced 2 kV line to earth 2 kV line to line Signal ports balanced 2 kV line to earth 1 kV line to line Power ports 2 kV line to earth 1 kV line to line EN 61000 4 6 conducted RF immunity Signal ports 10 V 80 AM 1 kHz 0 15 80 MHz Power ports 10 V 80 AM 1 kHz 0 15 80 MHz EN 61000 4 8 power frequency magnetic field Enclosure 300 A m EN 61000 4 9 pulsed magnetic field Enclosure 300 A m EN 61000 4 16 Mains freq 50 Hz Signal ports 100 V 50 Hz line to earth SS 436 15 03 Mains freq 50 Hz Signal ports 250 V 50 Hz line to line EN 61000 4 29 voltage dips and interruption DC power ports 10 100 ms interruption 10 ms 30 reduction 10 ms 60 reduction 20 above 20 below rated voltage EN 55022 radiated RF emission Enclosure Class A and Class B EN 55016 2 3 radieted emission Enclosure Class A and Class B FCC part 15 radiated RF emission Enclosure Class A and Class B EN 55022 conducted emission DC power ports Class A and Class B Safety Safety EN 60950 1 IT equipment UL IEC EN 60950 1 IT equipment EN 60950 1 dielectric strength Signal port to other isolated ports 1500 Vrms 50 Hz 1 min Power port to other isolated ports 1500 Vrms 50 Hz 1 min Climatic Temperature operating 40 to 70 C 40 to 158 F Temperature storage 40 to 70 C 40 to 158 F Maximum surface temperature 135 C temperature class T4 Humidity operating 5 to 95 relative humidity Humidity storage 5 to 95 relative humidity Enclosure Enclosure UL 94 aluminium zink flammability class V 0 Dimensions W x H x D 134 x 100 x 122 mm 5 25 x 3 93 x 4 80 in Weight 1 5 kg Degree of protection IP 40 Cooling Convection Mounting Horizontal on 35 mm DIN rail or wall mouonted Mechanical IEC 60068 2 6 vibration Operating 7 5 mm 5 8 Hz 2 g 8 500 Hz IEC 60068 2 27 shock Operating 15 g 11 ms Interface specifications power Rated voltage 20 to 48 VDC Operating voltage 16 to 60 VDC Rated current 330 mA 495 mA 20 VDC with 500 mA USB load 150 mA 215 mA 48 VDC with 500 mA USB load Rated frequency DC Inrush current 1 5 A2s Startup

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/A1F1167B260DB723C12578930033FA01 (2012-12-23)
    Open archived version from archive

  • Beijer Electronics - DDW-226
    V m 80 AM 1 kHz 1400 2100 MHz 5 V m 80 AM 1 kHz 2100 2500 MHz 1 V m 80 AM 1 kHz 2500 2700 MHz EN 61000 4 4 fast transients Signal ports 2 kV Power ports 2 kV EN 61000 4 5 surge Signal ports unbalanced 2 kV line to earth 2 kV line to line Signal ports balanced 2 kV line to earth 1 kV line to line Power ports 2 kV line to earth 1 kV line to line EN 61000 4 6 conducted RF immunity Signal ports 10 V 80 AM 1 kHz 0 15 80 MHz Power ports 10 V 80 AM 1 kHz 0 15 80 MHz EN 61000 4 8 power frequency magnetic field Enclosure 300 A m EN 61000 4 9 pulsed magnetic field Enclosure 300 A m EN 61000 4 16 Mains freq 50 Hz Signal ports 100 V 50 Hz line to earth SS 436 15 03 Mains freq 50 Hz Signal ports 250 V 50 Hz line to line EN 61000 4 29 voltage dips and interruption DC power ports 10 100 ms interruption 10 ms 30 reduction 10 ms 60 reduction 20 above 20 below rated voltage EN 55022 radiated RF emission Enclosure class A EN 55016 2 3 radieted emission Enclosure class A FCC part 15 radiated RF emission Enclosure class A EN 55022 conducted emission DC power ports class A Safety Safety EN 60950 1 IT equipment UL IEC EN 60950 1 IT equipment EN 60950 1 dielectric strength Signal port to other isolated ports 1500 Vrms 50 Hz 1 min Power portto other isolated ports 1500 Vrms 50 Hz 1 min Climatic Temperature operating 40 to 70 C 40 to 158 F Temperature storage 50 to 85 C 58 to 185 F Maximum surface temperature 135 C temperature class T4 Humidity operating 5 to 95 relative humidity Humidity storage 5 to 95 relative humidity Enclosure Enclosure UL 94 aluminium zink flammability class V 0 Dimensions W x H x D 134 x 105 x 122 mm Weight 1 5 kg Degree of protection IP 40 Cooling Convection Mounting Horizontal on 35 mm DIN rail or wall mouonted Mechanical IEC 60068 2 6 vibration IEC 60068 2 6 operating 7 5 mm 5 8 Hz 2 g 8 500 Hz IEC 60068 2 27 shock IEC 60068 2 27 operating 15 g 11 ms Interface specifications power Rated voltage 20 to 48 VDC Operating voltage 16 to 60 VDC Rated current 330 mA 495 mA 20 VDC with 500 mA USB load 150 mA 215 mA 48 VDC with 500 mA USB load Rated frequency DC Inrush current 1 5 A2s Startup current 400 mA Polarity Reverse polarity protected Redundant power input Yes Isolation to All other Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required Interface specifications console Electrical specification TTL level Data rate 115 2 kbit s Data format 8 data

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/E4E3CE65579FEFE2C12578930033FD83 (2012-12-23)
    Open archived version from archive


  • Beijer Electronics - L208-F2G-S2
    EN 61000 4 3 radiated RF immunity 20 V m 80 2700 MHz 1 kHz sine 80 AM EN 61000 4 6 conducted RF immunity Power port 10 V 80 AM 1 kHz 0 15 80 MHz Ethernet 10 V 80 AM 1 kHz 0 15 80 MHz Status out Digital in 10 V 80 AM 1 kHz 0 15 80 MHz Serial ports 10 V 80 AM 1 kHz 0 15 80 MHz Earth port 10 V 80 AM 1 kHz 0 15 80 MHz EN 55022 radiated RF emmision FCC Part 15 DNV 2 4 EN 55022 FCC Part 15 DNV 2 4 Class B DNV bridge EN 55022 conducted RF emmision FCC Part 15 DNV 2 4 EN 55022 FCC Part 15 DNV 2 4 Class B DNV bridge DNV 2 4 compass safe distance Standard compass 5 4 H deviation 15 cm Steering standby steering emergency compass 18 H deviation 10 cm Safety Safety UL IEC EN 60950 1 IT equipment EN 60950 1 dielectric strength Power port to all other ports 1 5 kVrms 50 Hz 1 min Ethernet ports to all other ports 1 5 kVrms 50 Hz 1 min RS 232 port to all other ports 1 5 kVrms 50 Hz 1 min RS 422 485 port to all other ports 1 5 kVrms 50 Hz 1 min Reliability prediction MTBF operating 499 000 hours Service life operating 10 years Climatic Temperature operating 40 to 70 C 40 to 158 F Temperature storage 50 to 85 C 58 to 185 F Humidity operating 5 to 95 relative humidity Humidity storage 5 to 95 relative humidity Enclosure Enclosure Fire enclosure Dimensions W x H x D 52 5 x 100 x 101 mm Weight 0 7 kg Degree of protection IP 40 Cooling Convection Mounting Horizontal on 35 mm DIN rail Mechanical IEC 60068 2 6 vibration IEC 60068 2 6 sine operating 3 13 2 Hz 1mm 13 2 100 Hz 0 7 g 5 5 30 Hz 1 5 g 30 50 Hz 0 42 mm 50 500 Hz 4 2 g IEC 60068 2 64 random operating 5 20 Hz 2 m s 20 2000 Hz 3 dB oct IEC 60068 2 27 shock Operating 30 g 11 ms 100 g 6 ms IEC 60068 2 27 bump Operating 10 g 11 ms Interface specifications power Operating voltage Rated 24 to 48 VDC Operating 19 to 60 VDC Rated current 250 mA 380 mA 24 VDC with 500 mA USB load 120 mA 188 mA 48 VDC with 500 mA USB load Rated frequency DC Inrush current 22 7 10 3 A2s 48 VDC Startup current 2 x Rated current Polarity Reverse polarity protected Redundant power input Yes Isolation to All other Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required Interface specifications 10 100BaseTX Electrical specification IEEE std 802 3 2005 Edition Data rate 10 Mbit s 100 Mbit s manual

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/87CD8DE1E0CA950DC12579E50041D195 (2012-12-23)
    Open archived version from archive

  • Beijer Electronics - L210-F2G
    EN 61000 4 4 fast transients Power port 2 kV Signal ports 2 kV Earth port 1 kV EN 61000 4 5 surge Power port L E 0 5 kV 12 Ω 9 μF L L 0 5 kV 2 Ω 18 μF L E 2 kV 42 Ω 0 5 μF L L 2 kV 42 Ω 0 5 μF L E 2 kV 12 Ω 9 μF L L 1 kV 12 Ω 9 μF Signal ports L E 1 kV 2 Ω L E 2 kV 42Ω 0 5 μF EN 61000 4 8 power frequency magnetic field 300 A m 0 16 7 50 Hz EN 61000 4 9 pulsed magnetic field 300 A m EN 61000 4 3 radiated RF immunity 10 V m 80 800 MHz 20 V m 800 1000 MHz 10 V m 1400 2100 MHz 5 V m 2100 2500 MHz 1 V m 2500 2700 MHz 1 kHz sine 80 AM EN 61000 4 6 conducted RF immunity Power port 10 V 80 AM 1 kHz 0 15 80 MHz Signal ports 10 V 80 AM 1 kHz 0 15 80 MHz Earth port 10 V 80 AM 1 kHz 0 15 80 MHz EN 55022 radiated RF emission Class A FCC part 15 radiated RF emission Class A EN 55022 conducted emission Power port Class B Signal ports Class B Safety Safety UL IEC EN 60950 1 IT equipment EN 60950 1 dielectric strength Power port to all other ports 1 5 kVrms 50 Hz 1 min Signal ports to all other ports 1 5 kVrms 50 Hz 1 min Reliability prediction MTBF operating 666 000 h MIL HDBK 217F Climatic Temperature operating 40 to 70 C 40 to 158 C Temperature storage 50 to 85 C 58 to 185 F Humidity operating 5 to 95 relative humidity Humidity storage 5 to 95 relative humidity Enclosure Dimensions W x H x D 52 5 x 100 x 101 mm With connectors 52 5 x 119 x 101 mm Weight 0 7 kg Degree of protection IP 40 Cooling Convection Mounting DIN rail Mechanical IEC 60068 2 27 shock 30 g 11 ms 100 g 6 ms IEC 60068 2 6 vibration 3 13 2 Hz 1mm 13 2 100 Hz 0 7 g 5 5 30 Hz 1 5 g 30 50 Hz 0 42 mm 50 500 Hz 4 2 g IEC 60068 2 27 bump 10 g 11 ms Interface specifications power Operating voltage Rated 24 to 48 VDC Operating 19 to 60 VDC Rated current 240 mA 24 VDC 120 mA 48 VDC Rated frequency DC Inrush current 22 7 10 3 A2s 48 VDC Startup current 2 x Rated current Polarity Reverse polarity protected Redundant power input Yes Isolation to All other Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required Interface specifications 10 100BaseTX Electrical specification IEEE std 802 3 2005 Edition Data rate 10

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/20D1E7B5D085F1C9C12579E50041DB96 (2012-12-23)
    Open archived version from archive

  • Beijer Electronics - FDV-206-1D-1S
    4 4 fast transients Signal ports 2 kV Power ports 2 kV EN 61000 4 5 surge Signal ports unbalanced 2 kV line to earth 2 kV line to line Signal ports balanced 2 kV line to earth 1 kV line to line Power ports 2 kV line to earth 2 kV line to line EN 61000 4 6 conducted RF immunity Signal ports 10 V 80 AM 1 kHz 0 15 80 MHz Power ports 10 V 80 AM 1 kHz 0 15 80 MHz EN 61000 4 9 pulsed magnetic field Enclosure 300 A m 6 4 16 μs pulse EN 61000 4 29 voltage dips and interruption DC power ports 10 100 ms interruption 10 ms 30 reduction 10 ms 60 reduction 20 above 20 below rated voltage EN 55022 radiated RF emission Enclosure class A FCC part 15 radiated RF emission Enclosure class A EN 55022 conducted emission AC power ports class B DC power ports class B FCC part 15 conducted emission AC power ports class B Safety EN 60950 1 dielectric strength EN 60950 1 IT equipment Climatic Temperature operating 20 to 70 C 4 to 158 F Temperature storage 40 to 85 C 40 to 185 F Humidity operating 5 to 95 relative humidity Humidity storage 5 to 95 relative humidity Enclosure Enclosure UL 94 PC ABS flammability class V 1 Dimensions W x H x D 53 x 103 x 103 mm 2 08 x 4 05 x 4 05 in Weight 0 4 kg Degree of protection IP 40 Cooling Convection Mounting Horizontal on 35 mm DIN rail Mechanical IEC 60068 2 6 vibration Operating 5 20 Hz 2 m s 20 200 Hz 3 dB oct 3 axis 3 30 min IEC 60068 2 27 shock Operating 6 ms 1000 m s 6 directions 3 shocks direction Interface specifications power Rated voltage 24 to 48 VDC Operating voltage 19 to 60 VDC Rated current 460 mA 24 VDC 220 mA 48 VDC Rated frequency DC Inrush current 1 mA s 24 VDC 3 mA s 48 VDC Startup current 760 mApeak 24 VDC 500 mApeak 48 VDC Polarity Reverse polarity protected Redundant power input Yes Isolation to All other Connection Detachable screw terminal Connector size 0 2 2 5 mm AWG 24 12 Shielded cable Not required Interface specifications RS 232 Electrical specification EIA RS 232 Data rate 300 bit s to 115 2 kbit s Data format 7 or 8 data bits Odd even or none parity 1 or 2 stop bits Protocol Transparent optimised by packing algorithm Circuit type SELV Transmission range 15 m 49 ft Isolation to Power DSL Ethernet Galvanic connection to USB Console Connection RJ 45 RJ 45 to RS 232 converter cable included Shielded cable Not required Conductive housing Yes Number of ports 1 Interface specifications 10 100BaseTX Electrical specification IEEE std 802 3 2005 Edition Data rate 10 Mbit s 100 Mbit s manual or auto Duplex Full or half manual or auto

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/7726EB767640EC0BC125789300341807 (2012-12-23)
    Open archived version from archive

  • Beijer Electronics - MRD-310
    efficiency is vital and the MRD 310 has a special low power mode to only be fully powered when needed The built in serial port offers a simple modem replacement solution with the benefit of not having to reprogram or change legacy components during an upgrade Downloads Technical data MRD 310 Product description Status Active Article number 3623 0001 Ports 2 x 10 Mbit s or 100 Mbit s Ethernet TX RJ 45 1 x 300 bit s to 115 2 kbit s D sub RS 232 1 x SIM slot Description Industrial mobile broadband 3G router GSM GPRS EDGE 3G HSPA Warranty period 5 Years Standard compliance R TTE Article 3 1a EN 60950 Safety EN 50385 EMF exposure Article 3 1b EN 301 489 1 ERM EMC EN 301 489 7 ERM EMC GSM EN 301 489 24 ERM EMC 3G Article 3 2 EN 301 908 1 ERM 3G EN 301 908 2 ERM 3G EN 301 511 GSM EMC Electromagnetic Compatibility EN 61000 6 1 Immunity residential environments EN 61000 6 2 Immunity industrial environments EN 61000 6 3 Emission residential environments EN 61000 6 4 Emission industrial environments EMC specifications EN 61000 4 2 ESD Enclosure contact 4 kV crit A Enclosure air 8 kV crit A IEC 61000 4 3 RF field AM modulated Enclosure 10 V m crit A 80 2700 MHz EN 61000 4 4 fast transients Signal ports 1 kV crit A Power ports 2 kV crit A EN 61000 4 5 surge Ethernet ports 1 kV direct crit A Power ports 0 5 kV line to earth crit A 0 5 kV line to line crit A EN 61000 4 6 conducted RF immunity All ports 10 V m crit A 0 15 80 MHz EN 55022 radiated RF emission

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/3CE4ECAF04EC1F33C1257893003407C7 (2012-12-23)
    Open archived version from archive

  • Beijer Electronics - MRD-330
    built in serial port offers a simple modem replacement solution with the benefit of not having to reprogram or change legacy components during an upgrade Downloads Technical data MRD 330 Product description Status Active Article number 3623 0101 Ports 2 x 10 Mbit s or 100 Mbit s Ethernet TX RJ 45 3 x 300 bit s to 115 2 kbit s D sub RS 232 2 x Digital Input 2 x Digital Output 1 x SIM slot Description Industrial mobile broadband 3G router GSM GPRS EDGE 3G HSPA Warranty period 5 Years Reliability prediction Service life operating Operating 10 year EMC Electromagnetic Compatibility EN 61000 6 1 Immunity residential environments EN 61000 6 2 Immunity industrial environments EN 61000 6 3 Emission residential environments EN 61000 6 4 Emission industrial environments EMC specifications EN 61000 4 2 ESD Enclosure contact 4 kV crit A Enclosure air 8 kV crit A IEC 61000 4 3 RF field AM modulated Enclosure 10 V m crit A 80 2700 MHz EN 61000 4 4 fast transients Signal ports 1 kV crit A Power ports 2 kV crit A EN 61000 4 5 surge Ethernet ports 1 kV direct crit A Power ports 0 5 kV line to earth crit A 0 5 kV line to line crit A EN 61000 4 6 conducted RF immunity All ports 10 V m crit A 0 15 80 MHz EN 55022 radiated RF emission Enclosure Class B EN 55022 conducted emission AC power ports Class B Ethernet ports Class B Safety EN 60950 1 dielectric strength Safety EN 60950 IT equipment Climatic Temperature operating 30 to 60 C 22 to 140 F Temperature storage 40 to 85 C 40 to 185 F Humidity operating 0 to 90 relative humidity non condensing Humidity storage 0 to

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/DB9D1BFA332CCCFDC125789300340B8B (2012-12-23)
    Open archived version from archive


archive-lv.com, 2017-08-17