archive-lv.com


Web directory, archive
Search archive-lv.com:


Find domain in archive system:
archive-lv.com » LV » B » BEIJER.LV

Total: 492

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Beijer Electronics - FX3U
    configure demand oriented and tailor made systems Depending on the application and the control requirements one can choose the compact and economic FX1S series the expandable FX1N series or the more powerful FX3U C series Both the FX1N and FX2N C series are good choices for plant installations since they can be expanded as needed for the application Tailor made systems can be configured by combining modules from many different categories All the modules are galvanically insulated with optical couplers for maximum safety Digital I O modules For many different signal types with relay or transistor outputs Analog I O modules For processing of current voltage signals and temperature recording with the capability of directly connecting PT100 sensors and thermal elements Positioning modules High speed counters with connection facilities for pulse sensors and positioning modules for servos and stepper motors Communications modules Interface modules with RS232 RS422 RS485 interfaces for connection to peripheral equipment and communications links to other PLC systems Network modules for PROFIBUS ASi CANopen DeviceNet Ethernet and for configuring Mitsubishi networks Digital and specialized modules configuration The ability to use digital and specialized modules depends on which central unit is used in the system When calculating the maximum number of specialised modules in a system account must be taken of both the number of digital modules and the maximum number of specialized modules that can be used The following table defines the number of modules that can be used for each system type Central unit system limitations FX1S Free standing PLC system with 10 14 20 or 30 inputs and outputs no specialized modules one function card FX1N PLC system with max 128 inputs and outputs maximum two specialized modules eight if an FX2N expansion unit is used one function card FX2N PLC system with max 256 inputs and outputs maximum eight 8 specialized modules one function card FX3U C PLC system with max 256 inputs and outputs maximum four specialized modules Communication Open networks The FX series can communicate in open standardised networks such as Ethernet CC Link Modbus and Profibus DP or in its own MELSEC network Ethernet Ready for immediate operation with the universal standard TCP IP protocol Communication by Ethernet between a PC and a PLC provides full access to process data uploading and downloading of programs and monitoring and trouble shooting A cost effective alternative at the control level Thanks to simple configuration commissioning is rapid even for complex applications CC Link CC Link is a network for the control and I O levels It has functions for program and data transfer and compact PLC systems can communicate via the same network Modules from third party suppliers can also be connected Data transfer speed up to 10 Mbit s Profibus DP Fast and easy connection to I O modules or PLC systems as a slave in the Profibus DP network FX3U C can also function as a master Data transfer speed of up to 12 Mbit s CANopen CANopen is a cost

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/EF5625C96B18E4FFC1257945003234C1 (2012-12-23)
    Open archived version from archive


  • Beijer Electronics - FX3UC
    Efficient and user friendly programming with IEC 61131 3 standardized software Connection options The STN terminal connection blocks and cables are adapted especially for FX3UC The STN series consists of a wide range of input and output blocks with screw terminals or tension clamps Design Expandable and flexible modular design The FX family includes a very wide choice of basic and expansion units which makes it possible to configure demand oriented and tailor made systems Depending on the application and the control requirements one can choose the compact and economic FX1S series the expandable FX1N series or the more powerful FX3U C series Both the FX1N and FX2N C series are good choices for plant installations since they can be expanded as needed for the application Tailor made systems can be configured by combining modules from many different categories All the modules are galvanically insulated with optical couplers for maximum safety Digital I O modules For many different signal types with relay or transistor outputs Analog I O modules For processing of current voltage signals and temperature recording with the capability of directly connecting PT100 sensors and thermal elements Positioning modules High speed counters with connection facilities for pulse sensors and positioning modules for servos and stepper motors Communications modules Interface modules with RS232 RS422 RS485 interfaces for connection to peripheral equipment and communications links to other PLC systems Network modules for PROFIBUS ASi CANopen DeviceNet Ethernet and for configuring Mitsubishi networks Digital and specialized modules configuration The ability to use digital and specialized modules depends on which central unit is used in the system When calculating the maximum number of specialised modules in a system account must be taken of both the number of digital modules and the maximum number of specialized modules that can be used The following table defines the number of modules that can be used for each system type Central unit system limitations FX1S Free standing PLC system with 10 14 20 or 30 inputs and outputs no specialized modules one function card FX1N PLC system with max 128 inputs and outputs maximum two specialized modules eight if an FX2N expansion unit is used one function card FX2N PLC system with max 256 inputs and outputs maximum eight 8 specialized modules one function card FX3U C PLC system with max 256 inputs and outputs maximum four specialized modules Communication Open networks The FX series can communicate in open standardised networks such as Ethernet CC Link Modbus and Profibus DP or in its own MELSEC network Ethernet Ready for immediate operation with the universal standard TCP IP protocol Communication by Ethernet between a PC and a PLC provides full access to process data uploading and downloading of programs and monitoring and trouble shooting A cost effective alternative at the control level Thanks to simple configuration commissioning is rapid even for complex applications CC Link CC Link is a network for the control and I O levels It has functions for program and data transfer and compact

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/3762A4C78E6F1C14C125794500414551 (2012-12-23)
    Open archived version from archive

  • Beijer Electronics - FX3G
    software Design Expandable and flexible modular design The FX family includes a very wide choice of basic and expansion units which makes it possible to configure demand oriented and tailor made systems Depending on the application and the control requirements one can choose the compact and economic FX1S series the expandable FX1N series or the more powerful FX3U C series Both the FX1N and FX2N C series are good choices for plant installations since they can be expanded as needed for the application Tailor made systems can be configured by combining modules from many different categories All the modules are galvanically insulated with optical couplers for maximum safety Digital I O modules For many different signal types with relay or transistor outputs Analog I O modules For processing of current voltage signals and temperature recording with the capability of directly connecting PT100 sensors and thermal elements Positioning modules High speed counters with connection facilities for pulse sensors and positioning modules for servos and stepper motors Communications modules Interface modules with RS232 RS422 RS485 interfaces for connection to peripheral equipment and communications links to other PLC systems Network modules for PROFIBUS ASi CANopen DeviceNet Ethernet and for configuring Mitsubishi networks Digital and specialized modules configuration The ability to use digital and specialized modules depends on which central unit is used in the system When calculating the maximum number of specialised modules in a system account must be taken of both the number of digital modules and the maximum number of specialized modules that can be used The following table defines the number of modules that can be used for each system type Central unit system limitations FX1S Free standing PLC system with 10 14 20 or 30 inputs and outputs no specialized modules one function card FX1N PLC system with max 128 inputs and outputs maximum two specialized modules eight if an FX2N expansion unit is used one function card FX2N PLC system with max 256 inputs and outputs maximum eight 8 specialized modules one function card FX3U C PLC system with max 256 inputs and outputs maximum four specialized modules Communication Open networks The FX series can communicate in open standardised networks such as Ethernet CC Link Modbus and Profibus DP or in its own MELSEC network Ethernet Ready for immediate operation with the universal standard TCP IP protocol Communication by Ethernet between a PC and a PLC provides full access to process data uploading and downloading of programs and monitoring and trouble shooting A cost effective alternative at the control level Thanks to simple configuration commissioning is rapid even for complex applications CC Link CC Link is a network for the control and I O levels It has functions for program and data transfer and compact PLC systems can communicate via the same network Modules from third party suppliers can also be connected Data transfer speed up to 10 Mbit s Profibus DP Fast and easy connection to I O modules or PLC systems as a slave in the

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/DDF4AF77BA95BFFBC125794800360B51 (2012-12-23)
    Open archived version from archive


  • Beijer Electronics - FX1S
    more powerful FX3U C series Both the FX1N and FX2N C series are good choices for plant installations since they can be expanded as needed for the application Tailor made systems can be configured by combining modules from many different categories All the modules are galvanically insulated with optical couplers for maximum safety Digital I O modules For many different signal types with relay or transistor outputs Analog I O modules For processing of current voltage signals and temperature recording with the capability of directly connecting PT100 sensors and thermal elements Positioning modules High speed counters with connection facilities for pulse sensors and positioning modules for servos and stepper motors Communications modules Interface modules with RS232 RS422 RS485 interfaces for connection to peripheral equipment and communications links to other PLC systems Network modules for PROFIBUS ASi CANopen DeviceNet Ethernet and for configuring Mitsubishi networks Digital and specialized modules configuration The ability to use digital and specialized modules depends on which central unit is used in the system When calculating the maximum number of specialised modules in a system account must be taken of both the number of digital modules and the maximum number of specialized modules that can be used The following table defines the number of modules that can be used for each system type Central unit system limitations FX1S Free standing PLC system with 10 14 20 or 30 inputs and outputs no specialized modules one function card FX1N PLC system with max 128 inputs and outputs maximum two specialized modules eight if an FX2N expansion unit is used one function card FX2N PLC system with max 256 inputs and outputs maximum eight 8 specialized modules one function card FX3U C PLC system with max 256 inputs and outputs maximum four specialized modules Communication Open networks The FX series can communicate in open standardised networks such as Ethernet CC Link Modbus and Profibus DP or in its own MELSEC network Ethernet Ready for immediate operation with the universal standard TCP IP protocol Communication by Ethernet between a PC and a PLC provides full access to process data uploading and downloading of programs and monitoring and trouble shooting A cost effective alternative at the control level Thanks to simple configuration commissioning is rapid even for complex applications CC Link CC Link is a network for the control and I O levels It has functions for program and data transfer and compact PLC systems can communicate via the same network Modules from third party suppliers can also be connected Data transfer speed up to 10 Mbit s Profibus DP Fast and easy connection to I O modules or PLC systems as a slave in the Profibus DP network FX3U C can also function as a master Data transfer speed of up to 12 Mbit s CANopen CANopen is a cost effective solution to integrate equipment at the I O level DeviceNet DeviceNet is based on the same network structure as CANopen and MELSEC a compact PLC system can communicate as

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/CDD0A8B5DCFF0663C125794800372EB3 (2012-12-23)
    Open archived version from archive

  • Beijer Electronics - iQ Works
    MT Works 2 Motion GT Works 3 GOT HMI Alpha Software Control units Decentralized I O systems Safety systems Robots Components Home Products Control systems Software iQ Works iQ Works Programming Suite for MELSEC PLC A complete suite of software from Mitsubishi Electric that minimizes engineering time across the entire chain of design programming commissioning and maintenance Parameter and network settings need only be done once for input system with

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/D98A3DAC685AA628C1257886004A983E (2012-12-23)
    Open archived version from archive

  • Beijer Electronics - Alpha Software
    With AL PCS you program directly into the function block diagram On start up a workspace is shown on the screen with empty boxes to the left and right sides In the left hand boxes are placed objects such as push buttons and temperature sensors In the right hand boxes are placed objects such as valves and lamps The function blocks that are needed are then placed in the work

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/1EA3C620DB9801B0C12578B60031FCBB (2012-12-23)
    Open archived version from archive

  • Beijer Electronics - RV-1A
    Drive systems Control systems Decentralized I O systems Safety systems Robots 6 axis robots RV 1A RV 3SDB RV 6SD RV 6SDL RV 12SDL 5 axis robots 4 axis robots Robot control system Software Accessories Components Home Products Robots 6 axis robots RV 1A RV 1A 6 axis robot 1kg This small 6 axis robot with its compact design and reliable construction makes it well suited to applications within quality

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/F758C92F1276A17FC1257968003E2E4A (2012-12-23)
    Open archived version from archive

  • Beijer Electronics - RV-3SDB
    6 axis robots RV 1A RV 3SDB RV 6SD RV 6SDL RV 12SDL 5 axis robots 4 axis robots Robot control system Software Accessories Components Home Products Robots 6 axis robots RV 3SDB RV 3SDB 6 axis robot 3 5kg With IP65 as standard six degrees of freedom and a payload of up to 3 5 kg the RV 3SDB can handle a broad spectrum of applications It has been

    Original URL path: http://www.beijer.lv/web/web_lv_be_lv.nsf/AllDocuments/2285F47578808727C1257968003EDCD8 (2012-12-23)
    Open archived version from archive


archive-lv.com, 2017-08-20