archive-lv.com


Web directory, archive
Search archive-lv.com:


Find domain in archive system:
archive-lv.com » LV » B » BALTICAQUA.LV

Total: 417

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Multipur AP
    impurities The filter can also be used to filter the well boiler make up process and cooling water The filter is not intended for the filtration of oils fats solvents soap solutions and other lubricating media and also for separating water soluble substances Principle of operation Untreated water enters the filter through the filter element from the steel Thus depending on the type of filter retains particles 100 mu m or 200 mu m These particles fall directly into the lower part of the body or retained on the filter element Backwash start automatically after a set interval between washes If due to increased contamination of the filter element differential pressure setpoint is exceeded before the end of the interval between two backwash rinsing will start immediately Backwash valve opens at the output of the wash water Segments of the suction ring element backwash move along the surface of the filter upward and backward filtration and sucked surface dirt If backwashing pass poorly the filter can be repeated up to 9 times washing Upon completion of high quality washing the filter will return to operation If all the backwash will fail will the fault Package includes Filter Cover Drive with magnetic valve and sensor Switchgear Pipe to connect the pipes to drain the wash water Pipe to connect the hose to drain the wash water Installation working conditions Filter at a distance of about 1 2 m should be a separate electrical outlet 230V 50Hz Shall be a continuous supply of electricity If the water contains particles of dirt the size of 2 mm in front of the filter should be installed filter strainer The feed rate of water during flushing backwash must be at least 6 m3 hour Protect from strong pressure shocks for example when closing the solenoid

    Original URL path: http://www.balticaqua.lv/index.php/en/drugaya-produktsiya/filtry-bwt/item/79-multipur-ap (2015-06-16)
    Open archived version from archive


  • RF-M
    pipes and the connected equipment fixtures appliances boilers production units from functional disturbances and corrosion caused by exposure to impurities The filter can also be used to filter the well boiler make up process and cooling water The filter does not provide for filtration of oils fats solvents soap solutions and other lubricating media and also for separating water soluble substances Operation During the filtration raw water passes through the filter element At the same time retains particles 100 mu m Depending on the size and weight of these particles fall directly into the bottom of the filter housing or retained on the inner surface of the filter element Backwash started turning the hand wheel Backwash valve opens at the output of the wash water Segments of the suction ring element backwash move along the surface of the filter from the bottom up and back and at the same time a very high speed is aspirated from the filter surface dirt Package includes Hand wheel 2 gauge Filter Drive to the membrane Installation working conditions Comply with local installation requirements general standards and specifications Set in a warm place away from heat sources with a temperature above 40 C protect the filter from solvent vapors diesel fuel alkaline solutions various chemicals and UV The feed rate of water during flushing backwash must be for RF and RF M 65 M 80 min 10 m3 hour for RF and RF M 100 M 125 min 14 m3 hour Warning Keep away from strong pressure shocks for example when closing the solenoid valve after the filter Specifications Operation presure 2 5 bar 1 0 bar Water temperature Environment 30 40 C Mounting position Main axis is vertical Fluid Drinking water Cell size 100 µm Throughput DN 65 35m ³ h 0 2

    Original URL path: http://www.balticaqua.lv/index.php/en/drugaya-produktsiya/filtry-bwt/item/80-rf-m (2015-06-16)
    Open archived version from archive

  • RF-A
    equipment boilers production units from functional disturbances and corrosion caused by exposure to impurities The filter can also be used to filter the well boiler make up process and cooling water Operation During the filtration raw water passes through the filter element Thus depending on the type of filter retains particles 100 mu m or 200 mu m These particles fall directly into the lower part of the housing or retained on the inner surface of the filter element Backwash valve opens at the output of the wash water Segments of the suction ring element backwash move along the bottom surface of the filter and back up and sucked into the filtration surface dirt Backwashing starts automatically as a result of contamination of the filter element value of the differential pressure reaches 0 8 bar factory setting If this pressure difference is not reached within a predetermined time interval backwashing begins at the end of this interval By electronic control units can be connected in parallel to 4 filters Package includes Drive with membrane 2 gauges Filter Housing with on LED red and green Control block Installation working conditions Filter at a distance about 1 2 m should be a separate electrical outlet 230V 50Hz Shall be a continuous supply of electricity The feed rate of water during flushing backwash models for RF and RF 65 A 80 A should be at least 10 m3 hour for model A RF 100 and RF 125 at least 14 m3 hour Protect from strong pressure shocks for example when closing the solenoid valve after the filter Specifications Operating presure 2 5 bar 1 0 bar Water temperature Environment 30 40 C Mounting position Main axis is vertical Fluid Drinking water Cell size 100 µm Throughput DN 65 35m ³ h 0 2

    Original URL path: http://www.balticaqua.lv/index.php/en/drugaya-produktsiya/filtry-bwt/item/81-rf-a (2015-06-16)
    Open archived version from archive


  • Avanti HWS
    редуктора давления Принцип действия Неочищенная вода поступает на станцию очистки через входное отверстие Во время забора воды обратный клапан открывается только в направлении течения В состоянии покоя или при противодавлении клапан герметично закрыт Вода проходит через фильтрующий элемент при этом на внутренней поверхности фильтровальной ткани остаются частицы размером 90 µм Фильтрующий элемент следует регулярно очищать путем обратной промывки Двухфазная обратная промывка запускается вручную При этом вначале после открывания рычага обратной

    Original URL path: http://www.balticaqua.lv/index.php/ru/drugaya-produktsiya/filtry-bwt/item/72-avanti-hws?tmpl=component&print=1 (2015-06-16)
    Open archived version from archive

  • Infinity
    отсасывает грязь Применение отсасывающего элемента позволяет достичь высокого перепада давления и вымывания частиц в отличие от промывки по всей поверхности фильтра Во время промывки фильтрация не прекращается Только 10 очищенной воды используется на промывку а остальная вода поступает потребителю Полимерный фильтрующий элемент эластичен поэтому хорошо очищается при промывке В отличие от нержавеющей стали он не подвержен влиянию железа и хлоридов Infinity A фильтр с автоматической обратной промывкой с выбором интервала времени между промывками Infinity AP фильтр с автоматической обратной промывкой электронным блоком управления с выбором интервала между промывками и дополнительно запуском обратной промывки от перепада давления на фильтрующей сетке Если в течение установленного интервала между промывками из за загрязнения фильтрующего элемента будет превышено настроенное значение дифференциального значения ок 0 8 бар датчик дифференциального давления запустит обратную промывку Отсчет установленного интервала между промывками запускается заново Модульная система присоединения фильтров позволяет производить монтаж на горизонтальных и вертикальных трубопроводах ТЕХНИЧЕСКИЕ ДАННЫЕ Рабочее давление min 2 bar max 16 bar Температура воды окружающей среды 30 40 C Установочная позиция Основная ось вертикально Жидкость Хозяйственная и питьевая вода Размер ячейки 90 110 µm Скорость потока воды DN 20 3 5 м ³ ч при 0 2 bar Δ p DN 25 4 5 м ³

    Original URL path: http://www.balticaqua.lv/index.php/ru/drugaya-produktsiya/filtry-bwt/item/73-infinity?tmpl=component&print=1 (2015-06-16)
    Open archived version from archive

  • Avanti RF
    следует регулярно очищать путем обратной промывки При вращении поворотной кнопки открывается слив промывочной воды и поворачивается элемент обратной промывки При этом отсасываются и вымываются частицы застрявшие в фильтровальной ткани ТЕХНИЧЕСКИЕ ДАННЫЕ Рабочее давление min 2 bar max 16 bar Температура воды окружающей среды 30 40 C Установочная позиция Основная ось вертикально Жидкость Хозяйственная и питьевая вода Размер ячейки 90 µm Пропускная способность DN 20 3 0 м ³ ч при

    Original URL path: http://www.balticaqua.lv/index.php/ru/drugaya-produktsiya/filtry-bwt/item/74-avanti-rf?tmpl=component&print=1 (2015-06-16)
    Open archived version from archive

  • Protector BW
    подсоединения шланга для сброса промывочной воды Вращающаяся кнопка для элемента обратной промывки Принцип действия Неочищенная вода поступает в фильтр и проходит через фильтрующий элемент наружу к выходу из фильтра При этом на внутренней стороне фильтровальной ткани задерживаются частицы 90 110 µм Во время обратной промывки при вращении кнопки открывается патрубок для слива промывочной воды и вращается элемент обратной промывки Частицы грязи скопившиеся на фильтровальной ткани отсасываются и вымываются ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ

    Original URL path: http://www.balticaqua.lv/index.php/ru/drugaya-produktsiya/filtry-bwt/item/75-protector-bw?tmpl=component&print=1 (2015-06-16)
    Open archived version from archive

  • Protector HW
    нарушений и коррозии вызываемых наличием посторонних примесей и взвесей Protector HW состоит из Головной и нижней части фильтра из латуни Переходников 3 4 1 Клапана для слива ТЕХНИЧЕСКИЕ ДАННЫЕ Рабочее давление min 2 bar max 16 bar Температура воды окружающей среды 5 80 о С 5 40 C Установочная позиция Основная ось вертикально Жидкость Хозяйственная и питьевая вода Размер ячеек 90 110 µm Расход воды DN 20 3 0 м

    Original URL path: http://www.balticaqua.lv/index.php/ru/drugaya-produktsiya/filtry-bwt/item/76-protector-hw?tmpl=component&print=1 (2015-06-16)
    Open archived version from archive



  •  


archive-lv.com, 2018-01-16